Microtek ONLINE UPS 40KVA, 3PH:3PH, ±192V (384V) HF SUPERMAX+ (WITH 4.3 INCHES TOUCH PANEL LCD DISPLAY)
₹389,999.99
Product Images
![]() |
![]() ![]() |
![](https://arbatteryhouse.com/wp-content/uploads/2024/01/online-ups-30kva-3ph3ph-192v-384v-hf-supermax-with-43-inches-touch-panel-lcd-display-3-1.webp)
![](https://arbatteryhouse.com/wp-content/uploads/2024/01/online-ups-30kva-3ph3ph-192v-384v-hf-supermax-with-43-inches-touch-panel-lcd-display-2.webp)
![](https://arbatteryhouse.com/wp-content/uploads/2024/01/online-ups-30kva-3ph3ph-192v-384v-hf-supermax-with-43-inches-touch-panel-lcd-display-4.webp)
Product Details
Microtek ONLINE UPS 40KVA, 3PH:3PH, ±192V (384V) HF SUPERMAX+ (WITH 4.3 INCHES TOUCH PANEL LCD DISPLAY)
SKU: 899-430-4002 | CATEGORY: ONLINE UPS
KEY FEATURES
- Unity Power Factor.
- DSP Technology with IGBT Based PFC and Inverter Section.
- Smart and Real time information Display.
- Frequency Converter Mode (50Hz/60Hz).
- ECO Mode Operation for Energy Saving.
- Active Power Factot Correction in all Phases.
- Bulit in Maintenance Bypass and Static Bypass Switches.
- Surge Protection at input.
- Adjustable Battery number (40-for long run Model).
- Waveform (Battery Mode) : Pure Sine Wave
WEIGHT: 91kg
DIMENSIONS (L W H): 30×81.5×100
Microtek offers 40KVA, 3PH:3PH, ±192V (384V) HF SUPERMAX+ (WITH 4.3 INCHES TOUCH PANEL LCD DISPLAY) Online Ups on World’s Latest Technology to meet the harsh Environmental and worst Power Conditions for Applications from Small Office requirement to Space Critical Missions with wide variety of Backup Range from 5 minutes to 10 hours to meet the needs of every individual.
Pure Sinewave Output Ratings starting from 6500i/96V to 11000i/180V Micro Processor based PWM Technology using Hi-Grade IGBTs Advance Battery Management (ABM) for Longer Battery Life and Quick Charging Static UPS with LCD Display Best Suited for most High Capacity Sophisticated Applications. Generator Compatible. In-built TDR (Time Delay Relay).
Advantages of using Microtek Online UPS
- Emergency Power Supply: – Whenever there is a power outage or shutdown, the UPS stands as a reliable and reliable power source. You can continue your work by using UPS or Batteries in the uncertain state of remote power disconnection.
- Protects the Voltage Sensitive Device from Bad Electricity: – You can detect power fluctuations in variable power leading to damage to the gadgets. The uninterruptible power supply provides stable output by controlling power fluctuations.
- Provides Surgical Protection: – In the event of a power outage, UPS detects improper power supply and stops direct power supply. Then it gives us stable energy from its stock. It prevents the cause of damage to the devices due to power supply interruptions.
- Battery Life Save: – You can continue working in operating mode even when the power is off as it keeps charging every time you connect the UPS to the battery.
Technical Specifications
MODEL SUPER MAX+ 40 KVA HIGH FREQUENCY ONLINE UPS | |
CAPACITY | 40KVA/ 40KW |
DC VOLTAGE | Default= +192VDC (32 Battery) Adjustable= +240 VDC (40 Battery) |
PHASE | 3 PHASE IN ~ 3 PHASE OUT |
INPUT | |
NOMINAL VOLTAGE | 3×400 VAC (3Ph+N) |
ACCEPTABLE VOLTAGE RANGE | 190~520VAC (3 PHASE) @ 50% Load 305~478VAC (3 PHASE) @ 100% Load |
FREQUENCY RANGE | 46~54 Hz or 56~64 Hz |
POWER FACTOR | > 0.99 @ 100% Load |
TOTAL HARMONIC DISTORTION THD(!) | <4% @ 100% R-Load, <5% @ 100% RCD Load at 230 VAC <6% @ 50% R-Load, <12% @ 50% RCD Load at 230 VAC |
OUTPUT | |
NOMINAL VOLTAGE | 3×360*/380/400/415 VAC (3Ph-N) |
AC VOLTAGE REGULATION | + 1% (Battery Mode) |
FREQUENCY RANGE | 46~54Hz or 56/64 Hz (Synchronized Range) 50Hz + 0.1Hz or 60Hz + 0.1 Hz (Battery Mode) |
CURRENT CREST RATIO | 3:1 (Max) |
HARMONIC DISTORTION | < 2% THD (Linear Load) : < 5% THD (Non-Linear Load) |
OVERLOAD CAPABILITY | AC MODE: (100%-110% : 60Min) (110%-125%:10Min) (125%~150%:1Min) >150% : Immediately BATTERY MODE:(100%-110%:60Min) (110%-125%:10Min) (125%~150%:1Min) >150%: Immediately |
TRANSFER TIME | |
AC MODE TO BATTERY MODE | ZERO |
INVERTER TO BYPASS | ZERO |
WAVEFORM (BATTERY MODE) | PURE SINE WAVE |
EFFICIENCY | AC MODE: 95.5% / ECO MODE: 98.5%, BATTERY MODE: 94.5% |
BATTERY | |
BATTERY TYPE | VRLA / LEAD-ACID TYPE |
NUMBERS OF BATTERY | Default: 32 Nos. – Adjustable: 40 Nos. (Note: Double Bank in Series of (16~29) + (16~20) Battery with Center-Tapped Confirguration) |
CHARGING CURRENT (MAX.) | 12A Maximum, adjustable = 1A to 12A, Factory Setting = 4A |
CHARGING VOLTAGE | +/- 13.65V*N (N=16~20) |
PHYSICAL | |
DIMENTIONS PRODUCT (LxWxH) | 815x300x1000 (in mm) |
NET WEIGHT PRODUCT (Kgs) | 61 Kgs. |
ENVIRONMENT | |
OPERATING HUMIDITY / TEMP. | <95% & Non-Condersing / 0.40°C |
NOISE LEVEL / INGRESS PROTECTION (IP RATING) | Less Than 65dB @ 1 Meter / IP-20 |
LCD INDICATION | UPS status, Load Percentage, Load Amperes on each phase, Output VA & Output Wattage per Phase, Battery Leval (Charging Ampere & Discharging Ampere), Input/Output Voltage (Phase to Neutral & Phase to Phase Voltage Information), Input/Output Frequency, Input Line Current per Phase, Input VA & Input Wattage Per Phase, Temperature Information and Data Log Events. |
MANAGEMENT | |
SMART RS-232 OR USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10 Linux & Mac |
OPTIONAL SNMP | Power Management From SNMP Manager and Web Browser |
Share Listing
Popular Products Overall
- Exide Inverter Battery IGST1500L/150AH (2378 views)
- Extreme Inverter Tubular Battery – HB150TT48/150AH (1409 views)
- Extreme Inverter Tubular Battery – AR24000HT/240AH (1319 views)
- Extreme Inverter Tubular Battery – AR21000HT/200AH (1268 views)
- Extreme Inverter Tubular Battery – AR18000HT/165AH (1124 views)
- Dynex Inverter Battery DTT2636/250AH (1115 views)
- Exide Inverter Battery IGTT1500L/150AH (1109 views)
- Extreme Inverter Tubular Battery – AR15000HT/150AH (1094 views)
- Dynex Inverter Battery DST1630/150AH (1059 views)
- EXIDE Home UPS set – STAR900 + IGST1500L/150AH (569 views)